What would you like help with today? Refrigerant manifolds can be convenient to charge the system after evacuation, but their hoses and valves can limit or slow evacuation. Repair or replacement decisions are at the sole discretion of Fieldpiece Instruments Inc. Three columns of LEDs in the oil window indicate various states. Its important to see the condition of your oil as well as the LED indicators located in the oil reservoir.The large oil drain ball valve will typically drain solids and sludge when changing the oil. Unscrew the pumps oil fill cap 1/4 turn counter clockwise. This new, larger window has additional LED lights that provide details on the status of the pump such as: gas ballast status, voltage levels/warnings and cold weather start status for the VP87 and VPX7 pumps. Always use fresh Fieldpiece vacuum pump oil. Do not connect or disconnect when energized, explosion risk. Do not use to pump flammable media, explosion risk. Saturated oil will look more opaque.Elevated Oil Drain Ball ValveBy elevating the oil reservoir and utilizing a fast opening ball valve, we made it easy to drain old oil into the empty bottle without a drop spilled.Oil Bottle Cap StorageWhen you open a fresh bottle of oil, put the cap on the side of the bottle so you can cap the bottle after you drain old oil into it.Wide Mouth Fill PortIt is easy to hit your target with the wide mouth fill port.Change Oil Quickly with the Pump RunningTowards the end of the evacuation is when you need fresh oil the most. Replace oil fill cap. We also offer oil designed for these new pumps that come in three options: a three-pack of eight-ounce containers; quart-size containers; or gallon-size containers. europe@fieldpiece.com, Fieldpiece Instruments Ltd To avoid breaking the window, start all 4 screws before hand-tightening any of them. Motor needs to be replaced.Motor thermal protection activated. After the appropriate vacuum is reached, isolate the system from the pump. And 15% off. Inhalation of high concentrations of refrigerant vapor can block oxygen to the brain causing injury or death. You can warm the oil in your truck/home before adding it to the pump. Store with ports capped to prevent dust from entering. The best Xtractor Depot deals. Fieldpiece Repair DepartmentPhone: (714) 634-1844. International WarrantyOutside the USA, please contact your distributor. Need to find a distributor near you? This machine is only intended for use by qualified personnel trained in servicing and installation of A/C/Refrigeration equipment. Oil can be drained while the pump is running if refilled within 3 minutes (within 30 seconds to maintain your vacuum). Motor does not start when switched ON.Models VPX7/VP87 have a soft-start feature that slowly increases speed during startup. Place the empty bottle under the drain valve so its ready to gather used oil during the next oil change. If desired, you can use a light bristle brush clean out the oil reservoir itself, but performance is rarely affected by a dirty reservoir. If the product is a non-warranty repair, we offer flat rate pricing (including shipping back). Only qualied personnel trained in service and installation of A/C and/or refrigeration equipment shall use this vacuum pump.This vacuum pump is used for evacuating (drying) refrigerant lines. Every product manual for every Fieldpiece product in an easily searchable database. Read and understand this operators manual in its entirety before using to prevent injury or damage to you or equipment. We know that for the HVACR pro time is money. Ensure proper voltage and cord length. Ensure oil is drained from the reservoir. Use vacuum rated hoses.Check for blockages between the pump and the system.Check for a system leak.Verify your vacuum gauge is in the correct location and is accurate. Answers to commonly asked questions about our products. The trade price for the VPX7 is $882, the VP87 is $723, and the VP67 is $470. Ensure the pump oil inside is warm enough, >75F (>24C), for proper drainage. The new Fieldpiece pumps include three different CFM models that can be used in a variety of applications. Connect multiple hoses to the inline ports on VPX7/VP87/VP67 to further decrease hose restriction and increase air flow. Switch your pump ON to create a vacuum at your gauge. Xtractor DepotPOS and Ecommerce by Shopify, Keep your extraction equipment top-of-the-line with the latest, CPS TR21X3 CPS TR21 Oilless Compressor Connecting Rod With Bearings (2), CPS TR21X1 CPS TR21 Oilless Compressor Valve Rebuild Kit, Edwards nXDS Series Dry Scroll Pumps Tip Seal Service Kit, MD4C NT Service Kit, PC201 NT, PC3003 & PC3004 VARIO. Fieldpiece entered the vacuum pump market with one goal: To provide the best possible solution. The quiet high speed fan cools the heat sinks of the motor and pump.Spare Oil Bottle StorageTake an extra bottle to and from the job site so you always have that fresh oil performance bump at the end of the job. Changing oil is easy and visible. This is the most common evacuation method. The wire with insulation having an outer surface that is green with or without yellow stripes is the grounding wire.Check with a qualified electrician or serviceman when the grounding instructions are not completely understood, or when in doubt as to whether the product is properly grounded. If you don't see your part listed in the drop down menu, please email us at . Clearly view the oil condition through the huge oil tank window. Any implied warranties arising from the sale of a Fieldpiece product, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited to the above. The extra wide base helps prevent tipping and spilling oil. Use the right pump for the job, 6CFM up to 10CFM (over 50 tons). fpsales@fieldpiece.com, Fieldpiece Instruments B.V. Before filling out the request form below, please note the following: All fields with an asterisk (*) are required. The blue lights of the middle column shine when the pump is switched on. Unscrew the brass EXHAUST cap and connect an obstruction-free garden hose if you need to exhaust oil mist and vapor remotely to the outside of a building structure. This machine should only be used for evacuation of refrigerant systems after refrigerant has been removed from the system and the system has been opened to atmosphere. This is usually the fastest evacuation method. Motor needs to be replaced.Motor may have come loose. Your product is under warranty *. Reinstall the bezel over the glass oil window using the 4 hex socket screws. For extended pump life, drain the oil immediately after the job instead of waiting until the beginning of the next job. Northampton, England NN3 6LG, Phone +800 789 789 78 Open an unused input port to ambient for a few seconds until the pump is running.Voltage is incorrect. Kings Park Road, Moulton Park Industrial Estate You will see tiny air bubbles with fresh oil. Plug into power to activate the oil backlight. Empty or replace oil at the end of every job. If you do not have proof of purchase, Fieldpiece will contact you if it is determined that your product is out of warranty. Always fill with fresh Fieldpiece Vacuum Pump Oil. (JavaScript must be enabled to view this email address), Please fill out below form completely and submit. Upon receipt of confirmation, Please print out the confirmation page and include in the box with your returning item(s). 2022 Fieldpiece Instruments, Inc. All rights reserved. Wipe with damp cloth to clean the exterior. Digital Manifold 40875 w/ 5/16 Compact Valve Hoses, Fieldpiece SM480V - Four Port, Wireless SMAN Manifold with Micron Gauge and Yellow Jacket 22985 Hoses, Fieldpiece SM380V w/Hoses | SMAN Manifold + Micron Gauge (3 Port) with Yellow Jacket 22985 hoses, YELLOW JACKET 93600 Bullet Single Phase Vacuum Pump, 7 Cfm, 115V, 60 Hz, Fieldpiece OIL128 Vacuum Pump Oil, 1 gallon (128 oz), Orion Motor Tech 3.5cfm Vacuum Pump, 1 Stage HVAC Vacuum Pump for R12 R22 R134a R410a Systems, Small 1/4hp 38 Micron Vacuum Pump for Air Conditioner Servicing Resin Degassing and More, Oil Included, VIVOHOME 110V 1/3 HP 4CFM Single Stage Rotary Vane Air Vacuum Pump and R134a AC Manifold Gauge Set Kit with Leak Detector Carry Bag for HVAC Air Conditioning Refrigeration Recharging ETL Listed, Fieldpiece OIL8X3 - Vacuum Pump Oil, Three Pack of 8 oz Containers, Fieldpiece HS36 Expandable Autoranging True RMS Stick Multimeter w/Backlight, Fieldpiece SC440 True RMS Clamp Meter with Temperature, Inrush Current, Capacitance and Backlight, Orion Motor Tech AC Vacuum Pump and Gauge Set, 4.5 cfm HVAC Vacuum Pump and 4 Way AC Gauges for R134a R410a R22 Refrigerants, with Leak Detector, Puncture and Self-Sealing Can Taps Quick Couplers, Appion MGAVCT 1/4" MegaFlow Vacuum-Rated Valve Core Removal Tool, Fieldpiece AAV3 Anemometer Air Velocity and Temperature Accessory Head, AUTOGEN 2-Stage Air Vacuum Pump 5CFM 3/4HP 0.3 Pa for HVAC/AUTO AC Refrigerant Recharging, Degassing Wine, Milking Cow, Food Processing, Fieldpiece SRS1 Residential, Light Commercial Refrigerant Scale, Fieldpiece ST4 Dual Temperature Meter, -58 to 2000F(-50 to 1300C), All customers get FREE Shipping on orders over $25 shipped by Amazon. Dont leave old oil in the machine. In your email please provide your Name, Address, Contact number, model number and describe the problem. Fax (714) 551-2299 This machine is warranted against defects in material or workmanship for one year from date of purchase from an authorized Fieldpiece dealer. In the USA, your Fieldpiece tools are warrantied against defects in material or workmanship for one year from date of purchase. The oil backlight helps to see the condition of the oil and if the ll level is correct.With the RunQuick oil change system, you can replace the oil in under 20 seconds without losing vacuum, even while the pump is running. For residential service and installation, HVACR pros will choose the VP67, 6CFM AC model, replacing the current VP55 (5CFM). Free ground shipping on Element, Media Bros, Carbon Chemistry, & Chemtek remediation powders. You can check the system for potential leaks at this time by monitoring your micron gauge. on Fieldpiece Vacuum Pump with RunQuick Oil Change System Owners Manual, Fieldpiece Vacuum Pump with RunQuick Oil Change System, Fieldpiece TC48 Large Pipe Clamp Type K Thermocouple User Manual, Fieldpiece DR82 Infrared (IR) Refrigerant Leak Detector User Manual, Fieldpiece RunQuick Vacuum Pump Oil Change System Owner's Manual, GROZ 5-Gallon Lever Oil Transfer Pump User Manual, NAVAC NRD24M 30M Dual-Stage Oil-sealed Rotary Vane Vacuum Pump User Manual, SEALEY AK450DP Air Operated Oil Pump Instructions, electro-harmonix Satisfaction Vintage Fuzz Pedal User Manual, sonicB SBBTH1 B.incognito Wireless Bluetooth Headphones User Guide, IKEA 905.039.16 HEMMAFIXARE Storage Case Instruction Manual, tedee TBV1.0 Set + Bridge Cylinder Installation Guide, ZERFUN G8 Pro Wireless Microphone System User Manual, Airrex Infrared Heater AH-200/300/800 User Manual, 2017 Toyota Camry Hybrid LE Fuse Box Diagrams, 2017 Mitsubishi Lancer 4WD Fuse Box Diagrams, Mitsubishi Lancer Passenger and Engine Fuse Box Diagram, Mira Honesty ERD Bar Valve and Fittings User Manual. (JavaScript must be enabled to view this email address)/*','a','/','<',' 109',' 111',' 99',' 46',' 101',' 99',' 101',' 105',' 112',' 100',' 108',' 101',' 105',' 102',' 64',' 121',' 116',' 110',' 97',' 114',' 114',' 97',' 119',' 112',' 102','>','\"',' 109',' 111',' 99',' 46',' 101',' 99',' 101',' 105',' 112',' 100',' 108',' 101',' 105',' 102',' 64',' 121',' 116',' 110',' 97',' 114',' 114',' 97',' 119',' 112',' 102',':','o','t','l','i','a','m','\"','=','f','e','r','h','a ','<'],i = l.length,j = el.length;while (--i >= 0)out += unescape(l[i].replace(/^\s\s*/, ''));while (--j >= 0)if (el[j].getAttribute('data-eeEncEmail_jNgcPaSUsx'))el[j].innerHTML = out;/*]]>*/. 2022 Fieldpiece Instruments, Inc. All rights reserved. The visual condition is one of them. Ensure the motor power switch is turned OFF (left). Open the oil drain valve clockwise (vertical) to empty the oil reservoir of old oil. What truly sets the VPX7 pump apart from the competition is the 10 CFM rate which will cut the evacuation time considerably, said Charlotte Loomis, Product Manager. This product is equipped with a cord having a grounding wire with an appropriate grounding plug. Enjoy all this and more when you sign up for the Xtractor Depot mailing list. 2022 Fieldpiece Instruments, Inc. All rights reserved. If you want to use a manifold, its best to use a 4 port manifold. We are happy to help. Search our global database. They also isolate the pump from the system and micron gauge without the need of a shut-off valve on the hose. Orange, CA 92867 Please include proof of purchase. The Fieldpiece top-of-the-line VPX7 pump is the lightest of the three new pumps due to a patent-pending manufacturing process resulting in a pump that is lightweight and manageable for the pro to carry. Top subscription boxes right to your door, 1996-2022, Amazon.com, Inc. or its affiliates. Drain oil after every job and store VPX7/VP87/VP67 empty to prevent spillage and reduced oil life. Exposure to refrigerant can cause frostbite. Please contact us. All products are warranted for one year from date of purchase only to original purchaser and are not transferable. Tighten motor mount bolts.Oil level or condition may be bad. Always fill with fresh Fieldpiece Vacuum Pump Oil (page 24). Ensure clean oil is added to a level between MIN and MAX lines. Do not use to remove refrigerant from a system. This extra step actually saves time overall because it quickly removes a great amount of moisture, oil, and other contaminants before you even connect your pump. 2022 Fieldpiece Instruments, Inc. All rights reserved. Fieldpiece refined the proprietary RunQuick Oil Management System by enlarging the oil-viewing window to clearly view the pump oil through the huge oil reservoir window to see the condition of the oil, and the system. Performing a triple evacuation is a great way to ensure a system is dry. Fieldpiece will replace or repair the defective unit, at its option, subject to verication of the defect.This warranty does not apply to defects resulting from abuse, neglect, accident, unauthorized repair, alteration, or unreasonable use of the machine.Any implied warranties arising from the sale of a Fieldpiece product, including but not limited to implied warranties of merchantability and tness for a particular purpose, are limited to the above. Clean the glass oil window and set aside to dry. Use a vacuum rated Schrader valve core removal tool to temporarily remove valve cores from service ports. This is a common, but less than ideal evacuation method. This field is for validation purposes and should be left unchanged. Motor may be damaged. Visit our website to nd your local distributor. Start each job with fresh oil. It is 4 to 12 alphanumeric characters long and always begins with a number. Looking to the future when A2L refrigerants will be required, the three models are A2L Refrigerant Compliant. Please enter the street address. This product must be grounded. Contact Us. Read the tech tips for optimum gauge placement and variations to reduce recovery times. Slowly remove the glass oil window while making sure to locate and remove the o-ring seal. P.O. The Netherlands, Toll free: +800 789 789 78* The above limitations or exclusions may not apply to you. The latest extraction products. Your vacuum pump is now ready to operate. The best Xtractor Depot deals. [CDATA[*/var out = '',el = document.getElementsByTagName('span'),l = ['>','a','/','<',' 109',' 111',' 99',' 46',' 101',' 99',' 101',' 105',' 112',' 100',' 108',' 101',' 105',' 102',' 64',' 121',' 116',' 110',' 97',' 114',' 114',' 97',' 119',' 112',' 102','>','\"',' 109',' 111',' 99',' 46',' 101',' 99',' 101',' 105',' 112',' 100',' 108',' 101',' 105',' 102',' 64',' 121',' 116',' 110',' 97',' 114',' 114',' 97',' 119',' 112',' 102',':','o','t','l','i','a','m','\"','=','f','e','r','h','a ','<'],i = l.length,j = el.length;while (--i >= 0)out += unescape(l[i].replace(/^\s\s*/, ''));while (--j >= 0)if (el[j].getAttribute('data-eeEncEmail_mVITKswiaH'))el[j].innerHTML = out;/*]]>*/ to request a repair RMA number. This is not a consumer machine. Place the glass oil window over o-ring and hold in place. State laws vary. The hottest industry news. Fieldpiece also included extra bottle storage. When it is time to change the oil, the process is quick, clean, and easy to do, as the window is now removable and the pumps have a wide mouth fill port. Use a shut-off valve at the third port to isolate the pump from the system.Check for a system leak. Disconnect from the system and unplug from power at the outlet. Connect to the empty, depressurized A/C system. Pour the entire 8 ounce bottle of fresh oil into the oil port and ensure the oil level is between the MIN and MAX lines indicated on the window bezel. Place the power cord on the handle for tangle free storage. This warranty does not apply to defects resulting from abuse, neglect, accident, unauthorized repair, alteration or unreasonable use of the instrument. Well typically respond to questions within 2 business days. The hottest industry news. Change as needed during the job. Fieldpiece Instruments, Inc. Edisonstraat 65 You can warm the oil in your truck/home before adding it to the pump.The pump may be cold. Oil backlight does not turn on when plugged in.Ensure power cord and outlet are functional. The LEDs of the left column typically indicate the gas ballast valve is open. Ensure the gas ballast is closed (vertical). You will receive RMA number immediately on the next page to send your product for Repair. Be careful using hoses. This machine is not to be used as a transfer pump for liquids or any other media; doing so can damage the product. Purge the A/C system with a few psi of dry nitrogen before evacuation to pre-dry the system. The micron gauge of a 3 port (2 valve) manifold cannot measure a systems vacuum if the valves are closed. Read the tech tips for optimum gauge placement and variations to reduce recovery times. For more information about the vacuum pumps please visit the product pagehttps://www.fieldpiece.com/product-category/recovery-and-vacuum/vacuum-pumps/. A unique online training platform for Fieldpiece products and applications. Close the valve counter clockwise (horizontal). Do not overtighten. Loading may be excessive. Slow startup in cold temperatures is normal.Oil in the pump may have become overly viscous due to contamination or low temperature. 2022 Fieldpiece Instruments, Inc. All rights reserved. to expose the pump to the system. Running the pump without oil will damage the pump and void the warranty. Use only within operating environment specification. * I understand that this online form is to request an RMA # for REPAIR ONLY (in-warranty repair or out-of-warranty repair). Read the tech tips (page12) for optimum gauge placement and variations to reduce recovery times. 9-inch Flexible Leak Detector Wand Extension, Replacement Filters and O-rings for Fieldpiece Refrigerant Leak Detectors, Replacement Heated Diode Refrigerant Sensor for SRL8/DR58, 9-inch Rigid Leak Detector Wand Extension, Barrel, Handle, Thermocouple and Hose for SOX3, Fuse 4-pack for SC66/67/76, HS 35/36, LT17A, and LT19A, Fuse 4-pack for LT83, LT83A, LT17 and HB74, 2-pack Battery Replacement for SPK1, SWT2, SIL2, SIP2. If you don't know the exact date of purchase, please input the best estimated date of purchase and we will contact you if it is determined that your product is out of warranty. They are available at distributors now. Check for leaks at connections. Do not use to pump liquid refrigerant, explosion risk. Fieldpiece shall not be liable for loss of use of the machine or other incidental or consequential damages, expenses, or economic loss, or for any claim of such damage, expenses, or economic loss.State laws vary. Wipe clean and make sure oil is not spilled when adding to the wide mouth oil fill port. Do not use solvents. Its best to use vacuum rated hoses, directly connected to core removal tools at the service ports. Warm the pump in your truck/home by letting it sit in warm environment. Ensure your old empty oil bottle is located under the oil drain. Open line set (hoses, manifolds, removal tools, etc.) Do not expose to rain, electrical shock risk. Store indoors. Fieldpiece Instruments introduces a new generation of vacuum pumps that are small, lightweight, portable, and allow fast, timesaving vacuum evacuation. Your email address will not be published. See our international distributors and their contact information. Fieldpiece Instruments, the industry leader in tools and test instruments for HVACR professionals, today announced a new generation of vacuum pumps that are small, lightweight, portable, and allow fast, timesaving vacuum evacuation to make the HVACR professionals job easier and more efficient. While holding the black bezel (frame) in place, use a hex key (Allen wrench) to remove the 4 hex socket screws. Fieldpiece shall not be liable for loss of use of the instrument or other incidental or consequential damages, expenses or economic loss, or for any claim of such damage, expenses or economic loss. Plug into an outlet (oil backlight should illuminate). 1636 West Collins Ave Register your Fieldpiece product to activate your warranty and receive software/firmware updates. While holding the glass oil window in place, remove the black bezel and notice the o-ring located behind the window. Doing so may damage or contaminate your vacuum pump. If it looks old, change it. Manufactured to a. Contact us for questions about your products warranty and for needed repairs. Drain the contaminated oil while the oil is still warm to keep the pump as clean as possible when stored. The latest extraction products. 888-733-2712 | M-F: 10am-6pm | Los Angeles | San Bernardino. Its part of being an HVACR professional. Hub SpotlightChase Wenger: Rooted in the Trades, Hub on the Road: Grassers Plumbing & Heating with Tim Kuhlman, Heat Pump Technology Driving Greenhouse Gas Reduction, https://www.fieldpiece.com/product-category/recovery-and-vacuum/vacuum-pumps/. The blue lights of the right column indicate power is connected. Include proof of purchase for warranty claims. Enjoy all this and more when you sign up for the Xtractor Depot mailing list. Ensure oil is fresh.Ensure oil level is between MIN and MAX lines.Ensure all port caps are closed and have working seals.Limit amount of connections. Use a recovery machine and filter to remove refrigerant and particles from the system before using VPX7/VP87/VP67 to evacuate the system. The patent-pending interior EPO coating, which is a high-energy surface treatment to high strength aluminum alloy, makes the VPX7 pump portable enough to climb up a ladder or move to other areas where needed. Inspect the machine and repair any damaged parts before using. Ensure the drain valve is closed (horizontal). Set here for initial pumping down (above 3000 microns) of wet systems. Keep your Fieldpiece products up-to-date with easy software and firmware updates. Handle with caution. Write the RMA# on the outside of the box and ship to Fieldpiece Instruments Inc. All returns must be shipped freight prepaid, * Warranty only applies if product is purchased from Fieldpiece Authorized dealer. As our latest innovations in the vacuum pump market, these workhorses cut evacuation time, so you can complete more jobs per day. Turn the motor power switch to ON (right). Open a new 8 ounce bottle of Fieldpiece Vacuum Pump Oil (OIL8X3). Ensure extension cord is grounded, 3 conductor, and is not damaged. Use fresh Fieldpiece Vacuum Pump Oil within the pumps operating temperature.The pump may be cold. The serial number is usually found on the back side of the product. For any other requests, email us at . Home Fieldpiece Fieldpiece Vacuum Pump with RunQuick Oil Change System Owners Manual. If youre in the United States, use the form below to request a repair. Office: +31 20 21 46 500 When it becomes hard to see through the window, you can remove the oil window for easy cleaning. Fieldpiece vacuum pumps provide a new view at system evacuation.Good oil is the lifeblood of every evacuation. Fieldpiece model MR45 is available for recovering refrigerant.Read and understand this operators manual in its entirety before using to prevent injury or damage to you or equipment. Much of the air and moisture in a system are removed before reaching 3000 microns. After viewing product detail pages, look here to find an easy way to navigate back to pages you are interested in. 7006 RB Doetinchem The RunQuick system maintains a vacuum for about 30 seconds after you drain the oil so you can drain and pump without any loss of vacuum.Precision Oil Circulator and FanInstead of submerging the pump in excess oil, a small oil pump constantly lubricates targeted sealing zones. If you need to replace a part, this is where youll find and order any Fieldpiece parts and accessories. Use this handy tool to compare the tech specs of our catalog of multimeters. You need to change the oil easily with no mess. Phone (714) 634-1844 Frostbite danger. When repair or replacement of the cord or plug is required, do not connect the grounding wire to either flat blade terminal. Change Oil Quickly, Even with the Pump Running, Cord Storage Integrated into Rubber Handle. Ensure motor power is switched OFF (left) before connecting or disconnecting power. Now, with our new VPX7, VP87 and VP67, were doing just that. Visit www.fieldpiece.com/rma for the latest information on how to obtain service.Warranty for products purchased outside of the U.S. should be handled through local distributors. Ensure the gas ballast is closed (vertical position, yellow LED off). Whether you have questions about a product, a new feature, or just want to say Hi, use the form below to contact Fieldpiece. Doing so helps the pump run smoothly and keeps the oil in good condition for when you need it most towards the end of the evacuation.At about 3000 microns, when the sound of the pump quiets down, the gas ballast should be closed so that a deep vacuum can be generated. Easy View Window and Oil BacklightThere are a few signs that remind you to change your oil. During the pull down, the systems vacuum level drops faster at the front of the system, near the vacuum pump.To ensure that your full system achieves the target micron level, place the vacuum gauge as far to the back of the system, away from the pump, as possible. Boxes are not allowed. The nitrogen flow can help carry moisture with it out of the system. Carry the machine to and from the job site easily and well protected. Always dispose of oil according to local jurisdiction. Put the bottle cap on the side of the bottle (CAP STORAGE). The new classification of A2L refrigerants has been addressed in this next generation vacuum pumps. Comment document.getElementById("comment").setAttribute("id","a8b84b099eb27422c30ee5414fc21b1b");document.getElementById("afe6277d1c").setAttribute("id","comment"); Save my name, email, and website in this browser for the next time I comment. Do not use in poorly ventilated enclosed areas. Oil mist is coming out of the exhaust.Some slight oil mist is normal due to airflow carrying oil as it passes through, and out of the pump.